SCIC-BNo centrifugal fan is a centrifugal fan with an indirect drive. It is a fan with 2 speeds, capable of changing the speed to change the flow according to the needs of users.
🔰 Uses
👉 Smoke extraction basement, fresh air supply pipe connection.
👉 Absorb the smell of gasoline in the parking garage.
👉 Smoke extraction from pipe shafts, building corridors…
🔰 Product Features
👉 Capable of changing speed to change flow and pressure through two-speed motor, belt transmission, pulley, shaft bearing.
👉 The fan can be fitted with conventional motors or fire-proof motors. Heat resistant from 2500C to 3000C for 2 hours of POWER, ENERTECH, TOAN PHAT, ABB, SIMENS,…
👉 Flexible disassembly for transportation to installation sites in buildings.
👉 Fabrication materials: steel, stainless steel
🔰 Specifications
No. |
Model |
D. of propeller (kW) |
Speed (Pole) |
Speed (V/ph) |
Voltage (V) |
Air Flow (m3/h) |
Pressure (Pa) |
1 |
SCIC-B3,2 |
320 |
0,75 |
6P |
380 |
1200-2200 |
150-300 |
1,1 |
4P |
380 |
2000-3200 |
220-450 |
2 |
SCIC-B4 |
400 |
0,75 |
6P |
380 |
2200-3800 |
160-350 |
1,5 |
4P |
380 |
3000-5000 |
240-500 |
3 |
SCIC-B5 |
500 |
1,5 |
6P |
380 |
3300-6000 |
200-380 |
3 |
4P |
380 |
8000-11000 |
240-520 |
4 |
SCIC-B6,3 |
630 |
3 |
6P |
380 |
7000-11000 |
200-420 |
5,5 |
4P |
380 |
12000-15000 |
250-600 |
5 |
SCIC-B7 |
700 |
4 |
6P |
380 |
10000-16000 |
200-450 |
7,5 |
4P |
380 |
20000-27000 |
300-700 |
6 |
SCIC-B8 |
800 |
5,5 |
6P |
380 |
15000-23000 |
300-550 |
11 |
4P |
380 |
24000-36000 |
400-900 |
7 |
SCIC-B10 |
1000 |
7,5 |
6P |
380 |
20000-30000 |
330-600 |
15 |
4P |
380 |
30000-40000 |
420-1200 |
8 |
SCIC-11 |
1100 |
11 |
6P |
380 |
25000-35000 |
350-660 |
22 |
4P |
380 |
45000-65000 |
450-1200 |
9 |
SCIC-B12 |
1200 |
15 |
6P |
380 |
45000-65000 |
400-800 |
30 |
4P |
380 |
70000-86000 |
500-1300 |
TECHNICAL DRAWING
🔰 Dimension
Model |
A |
A1 |
A2 |
B |
B1 |
B2 |
D |
D1 |
D2 |
L1 |
L2 |
3,2 |
220 |
300 |
220 |
300 |
300 |
370 |
720 |
580 |
380 |
360 |
590 |
4 |
270 |
350 |
270 |
350 |
300 |
370 |
420 |
570 |
420 |
380 |
650 |
5 |
320 |
400 |
320 |
400 |
350 |
420 |
900 |
790 |
480 |
490 |
800 |
6,3 |
440 |
540 |
440 |
540 |
450 |
520 |
1150 |
1040 |
500 |
820 |
1030 |
7 |
485 |
585 |
463 |
560 |
500 |
570 |
1200 |
1080 |
630 |
1080 |
115 |
8 |
600 |
700 |
500 |
600 |
700 |
770 |
1400 |
1100 |
600 |
1100 |
1200 |
10 |
800 |
900 |
600 |
700 |
800 |
880 |
1700 |
1200 |
700 |
1130 |
1400 |
11 |
800 |
900 |
600 |
700 |
800 |
880 |
1700 |
1200 |
800 |
1220 |
1800 |
12 |
900 |
1020 |
800 |
920 |
1050 |
1150 |
2000 |
1610 |
1050 |
1640 |
2000 |
🔰 Noise Table
Model |
3,2 |
3,8 |
4 |
5 |
5,5 |
6,3 |
7 |
8 |
10 |
11 |
12 |
12,5 |
12,9 |
SCD-BNo |
0,75 |
1,5 |
1,5 |
2,2 |
3 |
4 |
5,5 |
7,5 |
7,5 |
11 |
15 |
15 |
18,5 |
22 |
30 |
30 |
30 |
37 |
Inlet SPL dBA (Near Field) |
67 |
80 |
75 |
85 |
87 |
80 |
82 |
91 |
82 |
82 |
85 |
82 |
85 |
82 |
85 |
92 |
85 |
92 |
Outlet SPL dBA (Near Field) |
68 |
81 |
76 |
86 |
88 |
81 |
83 |
92 |
83 |
92 |
86 |
93 |
86 |
93 |
86 |
93 |
86 |
93 |
Cassing SPL dBA (3m) |
64 |
69 |
73 |
75 |
76 |
77 |
78 |
80 |
82 |
82 |
83 |
83 |
84 |
85 |
85 |
86 |
88 |
89 |
SYSTEM FAN GROUP
Specifications may change to meet your needs. Contact System Fan for advice and specific quotation.